Standard base |
A complex of technical hardware for reproducing, storing and transmitting a unit of laser radiation pulse duration in the range from 5·10-11 to 1·10-9 s as part of the State Primary Special Standard of Energy Units, distribution of energy density, pulse duration and wavelength of laser radiation GET 187-2016. GET 187-2016)
Installation for reproduction, storage and transmission of a unit of irradiance in the range from 10−8 to 10−6 W/m2 in the wavelength range from 0.2 to 0.4 µm. GET 162-2022)
|
PRODUCTS |
|
|
Streak cameras |
|
K008S Camera
Camera with full control from PC, designed to record and measure spatial-temporal parameters of high speed phenomena in single-frame and linear sweep modes with a maximum temporal resolution of ~ 50 ps
Made to order, the price is negotiable
Details…
|
|
|
K010X Soft X-ray camera
Camera is intended for registration of images of high speed phenomena in soft X-ray spectral range and measurements of spatial-temporal parameters in streak and single-frame modes with maximum temporal resolution of ~ 10 ps
Made to order, the price is negotiable
Details…
|
|
|
K011 Nine frame camera
Camera is intended for registration of images of high speed phenomena and measurements of spatial-temporal parameters in nine-frame mode.
Made to order, the price is negotiable
Details…
|
|
|
K016M Picosecond camera
Camera is intended for registration of images of high speed phenomena and measurements of spatial-temporal parameters in linear sweep mode with maximum temporal resolution of ≤ 2 ps.
Made to order, the price is negotiable
Details…
|
|
|
K018UV Camera
Camera is intended for registration of images of high speed phenomena in the visible UV and near infrared spectral ranges and measurements of spatial-temporal parameters in streak and single-frame modes
Made to order, the price is negotiable
Details…
|
|
|
ITAS-02 Time analyzing spectrograph
The spectrograph is designed to record the spectra of high speed phenomena in single-frame and linear sweep modes. It contains: monochromator-spectrograph SP-150 or DM 160 or another spectral device with output being connected to K018UV streak camera, three-axis adjustable platform for mounting a monochromator-spectrograph.
Made to order, the price is negotiable
Details…
|
|
Streak tubes |
|
PV-202 Streak tube
Metal-ceramic streak tube is designed to register high speed phenomena in single-frame and linear sweep modes. It has an S25 photocathode on a fiber optic disk, an electrostatic focusing system, one pair of sweep plates, a microchannel plate and a fluorescent screen on a fiber optic disk.
Made to order, the price is negotiable
Details…
|
|
|
PV-207 Streak tube
Metal-ceramic streak tube is designed to register high speed phenomena in linear sweep mode. It has an S25 photocathode, electrostatic focusing system, two pairs of sweep plates in two mutually perpendicular directions, and a luminescent screen on a fiber optic disk.
Made to order, the price is negotiable
Details…
|
|
|
PV-204X Streak tube
An open metal-to-glass streak tube is designed to register high speed phenomena in the soft X-ray and UV ranges in single-frame and linear sweep modes. It has an inlet vacuum flange on a bellows, replaceable CsJ and Au photocathodes, an electrostatic focusing system, one pair of sweep plates, a microchannel plate and a luminescent screen on a fiber optic disk.
Made to order, the price is negotiable
Details…
|
|
|
PIM-103 Streak tube
Streak tube is designed to register high speed phenomena in multi-frame and linear sweep modes. It has a photocathode, an electrostatic focusing system, an electronic shutter, sweep system with plates in two mutually perpendicular directions and a luminescent screen on a fiber optic disk.
Made to order, the price is negotiable
Details…
|
|
|
RM - 401X and RM - 402X Open flat X-ray streak tubes with microchannel plate
Streak tubes are designed to register short-wave radiation in the range from ultraviolet to hard X-rays, as well as various corpuscular flows - electrons, ions, etc in static and pulse modes of operation. They contain one or two microchannel plates and a luminescent screen on a fiber optic disk.
Made to order, the price is negotiable
Details…
|
|
Optical pulse generators |
|
L-04 Picosecond Optical Pulse Generator
Generator contains a laser diode and is designed for operational monitoring of performance and checking the spatial-temporal parameters of streak cameras in pico-nano-micro-millisecond ranges. It can be used to illuminate test objects, slits and frame fields of streak cameras in continuous and pulsed modes of operation. It can be used to measure temporal characteristics of photoelectric receivers and devices.
Made to order, the price is negotiable
Details…
|
|
|
L-05M Nano-millisecond optical pulse generator
Generator contains an LED and is designed for operational monitoring of performance and checking the spatial-temporal parameters of streak cameras with nano-micro-millisecond sweep ranges. It can be used to illuminate test objects, slits and frame fields of streak cameras, as well as other objects in continuous and pulsed modes of operation.
Made to order, the price is negotiable
Details…
|
|
Image readout systems |
|
RU-05M CCD camera
Camera is designed for recording and digital processing of continuous and pulsed images from the output of streak cameras, including images that appear at arbitrary times.
Made to order, the price is negotiable
Details…
|
|
|
RU-07 CCD camera
Camera with a fiber-optic input is designed for recording and digital processing of continuous and pulsed images from the output of streak cameras, including images that appear at arbitrary times.
Made to order, the price is negotiable
Details…
|
|
|
FOCL-01 Fiber optic communication line
Device is designed to connect television and streak cameras with a PC in conditions where connection using a conventional USB cable is impossible (electromagnetic interference, a large distance from the camera, background radiation, etc.). The line consists of a duplex multimode fiber optic cable of 100 or more meters in length, two transceivers and a power supply. The transceivers are converters of an electrical digital signal from USB standard into an optical one with a built-in four-port USB hub, allowing up to 4 streak cameras or other digitally controlled devices (oscilloscopes, monochromators, etc.) to be remotely connected to a PC through such a line.
Made to order, the price is negotiable
Details…
|
|
Standards |
|
State secondary standard of the unit of laser radiation pulse duration in the range from 3×10−12 to 1×10−9 s.
Standard is intended for reproducing, storing and transmitting a unit of laser radiation pulse duration in the range from 5×10-11 to 1×10-9 s.
Details…
|
|
|
Complex of technical hardware for reproducing, storing and transmitting a unit of laser radiation pulse duration in range from 5×10−11 to 1×10−9 s (is part of the GET 187-2016 State Primary Special Standard of Energy Units, distribution of energy density, pulse duration and wavelength of laser radiation)
The complex reproduces a unit of laser pulse duration in the range from 5×10−11 to 1×10−9 s at a wavelength of 0.755 μm.
Details…
|
|
|
Installation for reproduction, storage and transmission of a unit of irradiance in the range from 10−8 to 10−6 W/m2 in the wavelength range from 0.2 to 0.4 µm (is part of the GET 162-2022 State primary standard of units of radiation flux, energy illumination, spectral density of energy illumination and energy exposure in the wavelength range 0.0004 - 0.4 μm).
Installation is a part of the GET 162-2022 State primary standard of units of radiation flux, energy illumination, spectral density of energy illumination and energy exposure in the wavelength range 0.0004 - 0.4 μm.
Details…
|
|
Auxiliary equipment |
|
Optical trigger unit OTU-03
Device is designed to convert optical pulses supplied to it via fiber optics into electrical pulses for triggering various recording devices - streak cameras, oscilloscopes, etc.
Made to order, the price is negotiable
Details…
|