МЕТРОЛОГИЧЕСКИЕ УСЛУГИ

ЧАСТО ИНТЕРЕСУЮТСЯ

ПРЕЙСКУРАНТ НА ПОВЕРКУ СИ

ПРЕЙСКУРАНТ НА ПОВЕРКУ ЭТАЛОННЫХ СИ 

Эталонные средства измерений предназначены для поверки и калибровки рабочих средств измерений

Если у вас рабочее средство измерений, воспользуйтесь прейскурантом по ссылке выше

ВЫДАЧА И ПРИЕМ ВАШЕГО ОБОРУДОВАНИЯ

ПОДРОБНЕЕ ОБ УСЛУГАХ

Поверка СИ Калибровка СИ
Утверждение типа СИ Испытания СИ
Аттестация СИ и методик измерений

Посмотреть все услуги

ВОПРОСЫ ПО УСЛУГАМ

8 (800) 350 25 51
8 (495) 665 52 91
доб.3434
vniiofi@vniiofi.ru

ВОПРОСЫ ПО ПРИБОРАМ

8 (800) 350 25 51
8 (495) 665 52 91
доб.3535
vniiofi@vniiofi.ru
Small-sized nine-frame camera with full control from PC

Description

k011

Fields of application:

  • ballistic research;
  • studies of combustion, detonation, explosion, scattering of fragmentation fields, soil, etc;
  • shock waves physics;
  • plasma physics including thermonuclear synthesis;
  • electrical breakdowns and discharges.

line168

Contact details

(495) 437 34 74

Images obtained with K011 camera
 
Pic.1. Flight of a liquid drop, accelerated by a shock wave. Pic.2. Membrane rupture high gas pressure.
 
Main components of the camera:
  • input lens (a set of lenses is an option);
  • electromechanical shutter;
  • PIM-113 streak tube with S-25 photocathode applied on a fiber-optic disk, two pairs of deflecting plates, one microchannel plate (MCP) and luminescent screen applied on a fiber-optic disk;
  • power supply unit;
  • control unit with full control from PC;
  • RU-05M CCD camera (1392×1032 pixels, 12-bit ADC, linear dynamic range ≥ 300) with electric (≤ 5 m) or fiber optic (≤100 m) connection to PC;
  • neutral density filters D~0.5, 1, 2, installed on the input lens or on its seat;
  • frame window, installed close to the photocathode, defining visible frame area;
  • frame test object (GOI No. 4 test object), installed close to the cathode fiber-optic disk to perform spatial resolution check;
  • mounting plate for fixing the camera at the workplace.
Software:

Software allows to obtain visual and digital information about the registered process. Multi-window mode allows to work with multiple images. Images are saved in files, which, in addition to the image, can also contain metadata with information about the shooting conditions, as well as text comments.

Software Features:

  • configuring camera triggering settings;
  • correction of geometric and photometric distortions of the image, including the non-uniformity of the sweep coefficient;
  • calculation of the numerical characteristics of the image (brightness, duration, size, speed);
  • mage transformations.

Images can be exported to a standard 12-bit TIFF format for further processing in third-party software.

Operating conditions:
  • Humidity ≤ 80%
  • Temperature 283 – 308 К
  • Pressure – 105 kPa
Main Specifications
 
Spectral sensitivity range, nm
380 – ≥850
Maximum conversion coefficient, W/W
≥ 5000
Programmable duration of any frame, µs
0,06 – 500
Programmable duration of any  interframe pause, µs
0,04 – 500
Step for changing frame duration and interframe pause, μs
0,02
Spatial resolution on the photocathode, 1.p./mm
≥ 10
Maximum triggering frequency, limited by CCD camera, Hz
7,5
«Dead» time, ns
≤ 250
Programmable additional delay of triggering (with 20 ns step), ms
0 – 1,3
Frame size on the photocathode, mm x mm
8 х 8
Typical length of the communicational lane between the camera and PC, m:
- electrical cable
- fiber-optic cable

5
≤ 100
Dimensions (without input lens), mm х mm х mm
≤ 330 × 120 × 230
Weight, kg
≤ 5
Supply voltage,  V:
- alternating current with 50-60 Hz frequency
- constant current (option)

110 – 220 ± 20%
18 – 36
Power consumption, VA
≤ 30
 
Complete set
 
Name Q-ty Note
1 K011 Camera 1 With power supply unit,control unit, PIM-113 streak tube, electromechanical shutter, RU-05M CCD camera
2 Accessories, spare equipment and replacement parts:
2.1 Input lens 1 «MC ZENITAR – M2s» 2/50
2.2 M42×M42 Extension rings, length, mm:
7
14
28

1
1
1
For use with input lens
2.3 Neutral density filters:
D ~ 0.5
D ~ 1
D ~ 2

1
1
1
For mounting on the input lens
2.4 M49×M54 Adapter ring 1 To install filters on the input lens
2.5 M42×M54 Adapter ring 1 To install filters instead of the input lens
2.6 Mounting plate 1 Used to fix camera at work place
2.7 Fuse 1 A 2
2.8 Laptop with installed FastGlance software, USB flash drive with software and drivers, USB 2.0 cable to connect CCD camera. 1
2.9 Fiber optic communication line, ≤100m 1 Optional
3 Documentation:
3.1 User manual 1
3.2 FastGlance software User Guide 1
3.3 Package 1 Case
 
Small-sized camera with linear sweep and single-frame modes

Description

k010x

Fields of application:

  • laser physics;
  • nuclear physics;
  • plasma physics including thermonuclear synthesis;
  • electrical breakdowns and discharges;
  • x-ray spectroscopy.

line168

Contact details

(495) 437 34 74

Main components of the camera:
  • An open PV-204X streak tube with replaceable CsJ and Au photocathodes, microchannel plate (MCP), one pair of sweep plates and luminescent screen on a fiber optic disk.
  • power supply unit;
  • two interchangeable control units for microsecond and nanosecond sweep and frame ranges;
  • SDU RU-05M CCD camera (1392×1032 pixels, 12-bit ADC, linear dynamic range ≥ 300) with electric (≤ 5 m) or fiber optic (≤100 m) connection to PC;
  • laptop with installed software;
  • “In air” (etched in metal foil) test-objects – sweep test-object and GOI №4 frame test-object, installed close to the cathode to check spatial resolution;
  • mounting plate for fixing the camera at the workplace.
Software:

Software allows to obtain visual and digital information about the registered process. Multi-window mode allows to work with multiple images. Images are saved in files, which, in addition to the image, can also contain metadata with information about the shooting conditions, as well as text comments.

Software Features:

  • configuring camera triggering settings;
  • correction of geometric and photometric distortions of the image, including the non-uniformity of the sweep coefficient;
  • calculation of the numerical characteristics of the image (brightness, duration, size, speed);
  • image transformations.

Images can be exported to a standard 12-bit TIFF format for further processing in third-party software.

Operating conditions:
  • Humidity ≤ 80%
  • Temperature 283 – 308 К
  • Pressure 95 – 105 kPa
Main Specifications
 
Substrate material of replaceable CsJ and Au photocathodes:
- slit
- frame

parylene, 100 nm thickness
lavsan 3 µm thickness
Spectral sensitivity range of photocathode, keV:
- slit
- frame

≤ 0,1 – ≥ 10
≤ 0,6 – ≥ 10
Photocathode operating area, mm x mm:
- slit
- frame

≤ 0,1 × ≥ 15
≥ 6 × ≥ 12
Maximum current amplification factor in MCP
≥ 1000
Residual air in streak tube, operating pressure requirement, Pa
≤ 6 × 10-3
Sweep length, mm
18 – 20
Sweep coefficients:
- nanosecond control unit, ns/cm
- microsecond control unit, µs/cm

1 – 100
0,1 – 300
Non-uniformity of the sweep coefficient, %
≤ 5
Spatial camera resolution on the photocathode, 1.p./mm:
≥ 10
Limiting temporal resolution, ps
≤ 10
Trigger pulse requirements:
- polarity
- amplitude, V
- duration, ns
- rise time, ns

positive
≥ 2,5 – ≤ 50
≥ 10
≤ 50
Triggering level adjustment range, V
≤ 2,5 – ≥ 20
«Dead» time for the shortest sweep range:
- nanosecond control unit, ns
- microsecond control unit, µs

≤ 40
≤ 0,2
Frame duration:
- nanosecond control unit, ns
- microsecond control unit, µs

10 – 260
0,24 – 640
«Dead» time of the streak camera in single-frame mode:
- nanosecond control unit, ns
- microsecond control unit, µs

≤ 35
≤ 0,15
Maximum triggering frequency, Hz:
- nanosecond control unit
- microsecond control unit
(short range to long range)
- CCD Camera

10

1 – 10
7,5
Typical length of the communicational lane between the camera and PC, m:
- electrical cable
- fiber-optic cable

5
≤ 100
Dimensions, mm х mm х mm
≤ 440 × 110 × 200
Weight, kg
≤ 6
Supply voltage,  V:
- alternating current with 50-60 Hz frequency
- constant current (option)

160 – 260
18 – 36
Power consumption, VA
≤ 10
 
Complete set
 
Name Q-ty Note
1 K010X Camera (without control units) 1 Body with a power cable, power supply unit, PV-204X streak tube, RU-05M CCD Camera.
2 Accessories, spare equipment and replacement parts:
2.1 Changeable photocathodes:
- CsJ slit on parylene
- Au slit on parylene
- CsJ frame on lavsan
- Au frame on lavsan

4
2
2
2


Optional

Optional
2.2 Control unit CU-1 (nanosecond range) 1
2.3 Control unit CU-2 (microsecond range) 1
2.4 Laptop with installed FastGlance software, USB flash drive with software and drivers, USB 2.0 cable to connect CCD camera. 1
2.5 Fiber optic communication line, ≤100m 1 Optional
2.6 Coaxial cable 1 For camera triggering
2.7 CCD Synchronization cable 1
2.8 Test-objects:
- streak test-object
- GOI №4 frame test-object

1
1
To check spatial resolution
2.9 Mounting plate 1 Used to fix camera on work place
2.10 Fuse 2 A 1
2.11 Technological cap with centering and seal spacers 1 For sealing the streak tube bellows
2.12 Collar clamp 1 For docking transition pipe stub or technological cap with streak tube bellows
2.13 Set of devices for installing and replacing photocathodes and test objects in the streak tube 1
3 Documentation:
3.1 User manual 1
3.2 FastGlance software User Guide 1
3.3 Package 1 Case
 
Development and production of electronic-optical equipment for image registration and measurement of parameters of high speed phenomena
 
Managers

Deputy Head

Lavrukhina Elena

 

Contact details:

E.A. Lavrukhina: +7 495 437 34 74 (business phone), +7 926 038 21 32(cellphone).
e-mail: elavrukhina@vniiofi.ru

Due to the optimization in the field of electronic-optical instrumentation, in November 2021, BIFO company (www.bifocompany.com) became part of the R-5 department of VNIIOFI

   
Key areas of activity
  • Creation of standards and working measuring instruments for measuring the temporal characteristics of pulsed laser radiation.
  • Verification and calibration of equipment for measuring temporal and energy characteristics of optical radiation.
  • Carrying out theoretical and experimental research in the field of electrovacuum instrumentation.
  • Development of new technological processes, development and production of time-analyzing streak tube converters and brightness amplifiers.
  • Development of systems for remote control of the chemical composition of various media.
  • Development of systems for visualization and positioning of objects.
  • Development of systems for recording and processing images.
Main tasks
  • Development and production of electronic-optical equipment for image registration and measurement of parameters of high speed phenomena, such as:
    • combustion, explosion, shock and detonation waves, expansion of soil or elements of explosive shells and structures, ballistics of bodies tossed with up to cosmic velocities, and their interaction with an obstacle or target;
    • natural (lightning) and artificial electrical discharges in gas and other media;
    • various pulsed radiation in the range from near-IR to hard X-ray, including laser, interactions between matter and various types of radiation, including weak (with biological objects), powerful and super-powerful, both optical, laser, and corpuscular (electronic, ionic and other beams), etc.
  • Verification and calibration of electronic-optical measuring equipment.
  • Manufacture of streak tubes and streak tube based high-speed cameras, as well as auxiliary equipment - pulse generators, photo sensors for synchronizing cameras with processes, etc.
  • Commissioning of the supplied equipment, user training, equipment presentations, joint demonstration experiments and joint scientific research.
  • Warranty and post-warranty service of equipment.
Standard base

A complex of technical hardware for reproducing, storing and transmitting a unit of laser radiation pulse duration in the range from 5·10-11 to 1·10-9 s as part of the State Primary Special Standard of Energy Units, distribution of energy density, pulse duration and wavelength of laser radiation GET 187-2016. GET 187-2016)

Installation for reproduction, storage and transmission of a unit of irradiance in the range from 10−8 to 10−6 W/m2 in the wavelength range from 0.2 to 0.4 µm. GET 162-2022)

PRODUCTS
Streak cameras

K008S Camera

Camera with full control from PC, designed to record and measure spatial-temporal parameters of high speed phenomena in single-frame and linear sweep modes with a maximum temporal resolution of ~ 50 ps

Made to order, the price is negotiable

Details…


K010X Soft X-ray camera

Camera is intended for registration of images of high speed phenomena in soft X-ray spectral range and measurements of spatial-temporal parameters in streak and single-frame modes with maximum temporal resolution of ~ 10 ps

Made to order, the price is negotiable

Details…


K011 Nine frame camera

Camera is intended for registration of images of high speed phenomena and measurements of spatial-temporal parameters in nine-frame mode.

Made to order, the price is negotiable

Details…


K016M Picosecond camera

Camera is intended for registration of images of high speed phenomena and measurements of spatial-temporal parameters in linear sweep mode with maximum temporal resolution of ≤ 2 ps.

Made to order, the price is negotiable

Details…


K018UV Camera

Camera is intended for registration of images of high speed phenomena in the visible UV and near infrared spectral ranges and measurements of spatial-temporal parameters in streak and single-frame modes

Made to order, the price is negotiable

Details…


ITAS-02 Time analyzing spectrograph

The spectrograph is designed to record the spectra of high speed phenomena in single-frame and linear sweep modes. It contains: monochromator-spectrograph SP-150 or DM 160 or another spectral device with output being connected to K018UV streak camera, three-axis adjustable platform for mounting a monochromator-spectrograph.

Made to order, the price is negotiable

Details…

Streak tubes

PV-202 Streak tube

Metal-ceramic streak tube is designed to register high speed phenomena in single-frame and linear sweep modes. It has an S25 photocathode on a fiber optic disk, an electrostatic focusing system, one pair of sweep plates, a microchannel plate and a fluorescent screen on a fiber optic disk.

Made to order, the price is negotiable

Details…


PV-207 Streak tube

Metal-ceramic streak tube is designed to register high speed phenomena in linear sweep mode. It has an S25 photocathode, electrostatic focusing system, two pairs of sweep plates in two mutually perpendicular directions, and a luminescent screen on a fiber optic disk.

Made to order, the price is negotiable

Details…


PV-204X Streak tube

An open metal-to-glass streak tube is designed to register high speed phenomena in the soft X-ray and UV ranges in single-frame and linear sweep modes. It has an inlet vacuum flange on a bellows, replaceable CsJ and Au photocathodes, an electrostatic focusing system, one pair of sweep plates, a microchannel plate and a luminescent screen on a fiber optic disk.

Made to order, the price is negotiable

Details…


PIM-103 Streak tube

Streak tube is designed to register high speed phenomena in multi-frame and linear sweep modes. It has a photocathode, an electrostatic focusing system, an electronic shutter, sweep system with plates in two mutually perpendicular directions and a luminescent screen on a fiber optic disk.

Made to order, the price is negotiable

Details…


RM - 401X and RM - 402X Open flat X-ray streak tubes with microchannel plate

Streak tubes are designed to register short-wave radiation in the range from ultraviolet to hard X-rays, as well as various corpuscular flows - electrons, ions, etc in static and pulse modes of operation. They contain one or two microchannel plates and a luminescent screen on a fiber optic disk.

Made to order, the price is negotiable

Details…

Optical pulse generators

L-04 Picosecond Optical Pulse Generator

Generator contains a laser diode and is designed for operational monitoring of performance and checking the spatial-temporal parameters of streak cameras in pico-nano-micro-millisecond ranges. It can be used to illuminate test objects, slits and frame fields of streak cameras in continuous and pulsed modes of operation. It can be used to measure temporal characteristics of photoelectric receivers and devices.

Made to order, the price is negotiable

Details…


L-05M Nano-millisecond optical pulse generator

Generator contains an LED and is designed for operational monitoring of performance and checking the spatial-temporal parameters of streak cameras with nano-micro-millisecond sweep ranges. It can be used to illuminate test objects, slits and frame fields of streak cameras, as well as other objects in continuous and pulsed modes of operation.

Made to order, the price is negotiable

Details…

Image readout systems

RU-05M CCD camera

Camera is designed for recording and digital processing of continuous and pulsed images from the output of streak cameras, including images that appear at arbitrary times.

Made to order, the price is negotiable

Details…


RU-07 CCD camera

Camera with a fiber-optic input is designed for recording and digital processing of continuous and pulsed images from the output of streak cameras, including images that appear at arbitrary times.

Made to order, the price is negotiable

Details…


FOCL-01 Fiber optic communication line

Device is designed to connect television and streak cameras with a PC in conditions where connection using a conventional USB cable is impossible (electromagnetic interference, a large distance from the camera, background radiation, etc.). The line consists of a duplex multimode fiber optic cable of 100 or more meters in length, two transceivers and a power supply. The transceivers are converters of an electrical digital signal from USB standard into an optical one with a built-in four-port USB hub, allowing up to 4 streak cameras or other digitally controlled devices (oscilloscopes, monochromators, etc.) to be remotely connected to a PC through such a line. 

Made to order, the price is negotiable

Details…

Standards

State secondary standard of the unit of laser radiation pulse duration in the range from 3×10−12 to 1×10−9 s.

Standard is intended for reproducing, storing and transmitting a unit of laser radiation pulse duration in the range from 5×10-11 to 1×10-9 s.

Details…


Complex of technical hardware for reproducing, storing and transmitting a unit of laser radiation pulse duration in range from 5×10−11 to 1×10−9 s (is part of the GET 187-2016 State Primary Special Standard of Energy Units, distribution of energy density, pulse duration and wavelength of laser radiation)

The complex reproduces a unit of laser pulse duration in the range from 5×10−11 to 1×10−9 s at a wavelength of 0.755 μm.

Details…


Installation for reproduction, storage and transmission of a unit of irradiance in the range from 10−8 to 10−6 W/m2 in the wavelength range from 0.2 to 0.4 µm (is part of the GET 162-2022 State primary standard of units of radiation flux, energy illumination, spectral density of energy illumination and energy exposure in the wavelength range 0.0004 - 0.4 μm).

Installation is a part of the GET 162-2022 State primary standard of units of radiation flux, energy illumination, spectral density of energy illumination and energy exposure in the wavelength range 0.0004 - 0.4 μm.

Details…

Auxiliary equipment

Optical trigger unit OTU-03

Device is designed to convert optical pulses supplied to it via fiber optics into electrical pulses for triggering various recording devices - streak cameras, oscilloscopes, etc.

Made to order, the price is negotiable

Details…

Note: in addition to the specified electronic-optical and optical-electronic devices, it is possible to develop devices according to individual requirements of the consumer.

Small-sized camera with linear sweep and single-frame modes with full control from PC

Description

k008s

Fields of application:

  • ballistic research;
  • studies of combustion, detonation, explosion, scattering of fragmentation fields, soil, etc;физика ударных волн;
  • shock waves physics;
  • laser physics;
  • nonlinear optics;
  • nonstationary spectroscopy;
  • nuclear physics;
  • plasma physics including thermonuclear synthesis;
  • electrical breakdowns and discharges including lightning;
  • ecology (a recorder in LIDAR systems for detection and determination of air or water pollution’s  location, size and chemical composition), etc.

line168

Contact details

(495) 437 34 74

Main components of the camera:
  • input lens (a set of lenses is an option);
  • electromechanical shutter;
  • PV-202 time-analyzing streak tube with S-25 photocathode applied on a fiber-optic disk, pair of deflecting plates, one microchannel plate (MCP) and luminescent screen applied on a fiber-optic disk;
  • power supply unit;
  • three interchangeable control units for millisecond, microsecond and nanosecond sweep and frame ranges;
  • SDU R-205 CCD camera (1392×1032 pixels, 12-bit ADC, linear dynamic range ≥ 300) with electric (≤ 5 m) or fiber optic (≤100 m) connection to PC;
  • laptop with installed software;
  • three interchangeable slits with width of 0.05, 0.1 and 0.2 mm, installed close to the cathode fiber-optic disk;
  • test-objects – slit test-object and frame test object (GOI No. 4 test object), installed close to the cathode fiber-optic disk to perform spatial resolution check;
  • neutral density filters D~0.5, 1, 2, installed on the input lens or on its seat;
  • mounting plate for fixing the camera at the workplace.
Software:

Software allows to obtain visual and digital information about the registered process. Multi-window mode allows to work with multiple images. Images are saved in files, which, in addition to the image, can also contain metadata with information about the shooting conditions, as well as text comments.

Software Features:

  • configuring camera triggering settings;
  • correction of geometric and photometric distortions of the image, including the non-uniformity of the sweep coefficient;
  • calculation of the numerical characteristics of the image (brightness, duration, size, speed);
  • image transformations.

Images can be exported to a standard 12-bit TIFF format for further processing in third-party software.

Operating conditions:
  • Humidity ≤ 80%
  • Temperature 283 – 308 К
  • Pressure 95 – 105 kPa
Main Specifications
 
Spectral sensitivity range, nm
380 – ≥ 850
Spectral sensitivity of the photocathode, at maximum of spectral range, mA/W
≥ 20
Maximum conversion coefficient, W/W
≥ 5000
Input lens focal length, mm:
- standard lens
- additional (option)

50
50 – 5000
Length of slit image on streak tube photocathode, mm
≥12,5
Sweep length, mm
18 – 20
Sweep coefficients:
- nanosecond control unit, ns/cm
- microsecond control unit, µs/cm
- millisecond control unit, ms/cm

1 – 100
0,1 – 300
0,1 – 300
Non-uniformity of the sweep coefficient, %
≤ 5
Spatial camera resolution on the photocathode, 1.p./mm:
- nanosecond control unit, ns
- microsecond control unit, µs
- millisecond control unit, ms

≥ 10
≥ 15
≥ 15
Limiting temporal resolution at 800 nm wavelength, ps
≤ 50
«Dead» time for the shortest sweep range:
- nanosecond control unit, ns
- microsecond control unit, µs
- millisecond control unit, ms

≤ 40
≤ 0,2
≤ 0,2
Frame size on the photocathode, mm x mm
≥12,5 × 12,5
Frame duration:
- nanosecond control unit, ns
- microsecond control unit, µs
- millisecond control unit, ms

10 – 260
0,24 – 640
0,24 – 640
«Dead» time of the streak camera in single-frame mode:
- nanosecond control unit, ns
- microsecond control unit, µs
- millisecond control unit, ms

≤ 35
≤ 0,15
≤ 0,2
Maximum triggering frequency, Hz:
- nanosecond control unit
- microsecond control unit
(short range to long range)
- millisecond control unit
(short range to long range)
- CCD Camera

100
30 – 3

10 – 1

7,5
Typical length of the communicational lane between the camera and PC, m:
- electrical cable
- fiber-optic cable

5
≤ 100
Dimensions (without input lens), mm х mm х mm
≤ 310 × 110 × 210
Weight, kg
≤ 5
Supply voltage,  V:
- alternating current with 50-60 Hz frequency
- constant current (option)

110 – 220
18 – 36
Power consumption, VA
≤ 35
 
Complete set
 
Name Q-ty Note
1 K008S Camera (without input lens and control units) 1 Body with a power cable, power supply unit, PV-202 streak tube, CCD Camera SDU R-205.
2 Accessories, spare equipment and replacement parts:
2.1 Input lens 1 «MC ZENITAR – M2s» 2/50
2.2 Control unit CU-1 (nanosecond range) 1
2.3 Control unit CU-2 (microsecond range) 1
2.4 Control unit CU-2 (millisecond range) 1
2.5 Coaxial cable 1 For camera triggering
2.6 Replaceable slits with width of, mm:
0,05
0,1
0,2

1
1
1
2.7 Neutral density filters:
D ~ 0.5
D ~ 1
D ~ 2

1
1
1
For mounting on the input lens
2.8 M49×M54 Adapter ring 1 To install filters on the input lens
2.9 M42×M54 Adapter ring 1 To install filters instead of the input lens
2.10 M42×M42 Extension rings, length, mm:
7
14
28

1
1
1
For use with input lens
2.11 Test-objects:
- streak test-object
- GOI №4 frame test-object

1
1
To check spatial resolution
2.12 Mounting plate 1 Used to fix camera on work place
2.13 Fuse 1 A 2
2.14 Laptop with installed FastGlance software, USB flash drive with software and drivers, USB 2.0 cable to connect CCD camera. 1
2.15 Fiber optic communication line, ≤100m 1 Optional
3 Documentation:
3.1 User manual 1
3.2 FastGlance software User Guide 1
3.3 Package 1 Case
 
Available camera options:
  • К008-S/1 – Camera with CU-1 control unit. Nanosecond sweep ranges.
  • К008-S/2 – Camera with CU-2 control unit. Microsecond sweep ranges.
  • К008-S/3 – Camera with CU-3 control unit. Millisecond sweep ranges.
  • К008-S/1/2 – Camera with CU-1 and CU-2 control units. Nano- and microsecond sweep ranges.
  • К008-S/1/2/3 – Camera with CU-1 and CU-2/3 control units. Nano-, micro- and millisecond sweep ranges. CU-2/3 control unit combines functions of both CU-2 and CU-3.
 
Device is designed to convert optical pulses supplied to it via fiber optics into electrical pulses for triggering various recording devices - streak cameras, oscilloscopes, etc.

Description

otu-03

zakazat

line168

Contact details

(495) 437 34 74

Main components:
  • avalanche photodiode S5139 type (Hamamatsu Photonics);
  • photodiode signal amplifier and output pulse shaper;
  • secondary power supply with adjustable voltage on the photodiode;
  • primary power source - built-in rechargeable battery;
  • battery charger.
Fields of application:

Synchronization of various recording devices - streak cameras, oscilloscopes, etc. with pulsed optical processes in such fields as:

  • shock waves physics;
  • laser physics;
  • nuclear physics;
  • plasma physics;
  • electrical breakdowns and discharges including lightning.
Operating conditions:
  • Humidity ≤ 80%
  • Temperature 283 – 308 К
  • Pressure 95 - 105 kPa
Main Specifications
 
Spectral sensitivity range, nm
400 – 1000
Wavelength corresponding to the maximum sensitivity, nm
800
Diameter of the photosensitive surface of the photodiode, mm
0,5
Diameter of the entrance lens, mm
1,5
Minimum energy of the triggering pulse (Emin) with duration 30 ns (λ = 630 nm), fJ:
- at the maximum sensitivity of the block (Emin1)
- at the minimum sensitivity of the block (Emin2)

≤ 50
≤ 500
"Dead" time at the energy of the triggering pulse E = 10 Emin, ns:
- at maximum sensitivity
- at the minimum sensitivity

≤ 30
≤ 35
Jitter - periodic instability of the "dead" time at the energy of the triggering pulse E = 10 Emin, ns
≤ 0,5
Parameters of the output synchronization pulse at a load of 50 ohms:
- polarity
- amplitude, V
- duration, ns
- rise time, ns

+
6 – 10
100 – 250
≤ 10
Supply voltage from the built-in battery, V
6 – 9
Power consumption, VA
≤ 3
Charger supply voltage with frequency of 50 - 60 Hz, V
110 – 220
Time of continuous operation from the battery, hour
≥ 6
Charging time of a completely discharged battery, hour
≤ 24
Overall dimensions, mm
180 х 95 х 65
Weight, kg
≤ 0,4
 
Complete set
 
Name Q-ty Note
1 OTU-03 Optical trigger unit 1
2 User manual 1
3 Package 1 Case
 

Государственные эталоны

Prev Next

Разработки и научные центры

Двойные стандарты? Нарушено единство измерений? Расскажите нам о проблемах
Госуслуги
Решаем вместе

 


Copyright ВНИИОФИ | 2009 - 2025 | Написать разработчику |
Яндекс.Метрика